Skip to main content

Water distribution system monitoring for leak detection

Hi-Leak: Innovative monitoring system for early leak detection in water distribution systems

Background

In Malaysia, current government initiatives are aimed at raising the financial and environmental sustainability of the water services industry by reaching 99% of coverage of clean and treated water and reduce NRW to 25% by 2020. Pipe failures for Malaysia’s non-revenue water are currently 39%, of which ~26% is lost through damaged water pipes and ~6% through inaccurate meter reading. The Ministry of Works estimates about RM25bn for water pipeline rehabilitation over the next 50 years including the replacement of over 44,000km of old asbestos-cement pipes with polyethylene pipes. It is intended that all the leaks detected are repaired by completely replacing the old pipes with new PE ones. Asbestos cement construction represents a significant percentage of the pipes installed in the Malaysian water distribution network, a network of 88,786 km of pipelines that supplies about 11bn m3 of water per year (expected to increase by 63% in 2050) to a total population of about 26 million. Current methods to identify leaks in this network include establishing district metered areas, visual inspections, insertion surveys (inserting microphones into water pipes) and correlation surveys (based on signal correlation techniques) which are all labour intensive and which efficiency largely depends on operator skills. In addition, leaks in non-ferrous mains often have relatively low noise frequencies that are almost impossible to detect with typical leak noise correlators. Considering the limitation of current methods and the lack of experienced manpower for inspection, the industry is looking at new technologies to monitor leaks without human intervention.

Objectives

The objective of this project is to optimise the detection of water leaks occurring in PE water pipes using distributed guided waves ultrasonic sensors with AE capabilities. HiLeak will be installed along pipes to autonomously detect and report leaks. In order to keep costs as low as possible, the system should rely on relatively simple hardware components and, consequently, the project will take into account only basic signal processing techniques.

Benefits

The HiLeak project will allow Brunel to advance the knowledge in the applicability of UGW for water filled polyethylene pipes monitoring, pushing further the monitoring range in non-metallic materials to notify in advance of pending failures via bespoke signal processing.

Brunel Innovation Centre's Roie

  • Optimisation of data analysis with development and use of novel models for data interpretation related to ultrasonic guided wave behaviour in polyethylene pipes. Brunel will develop a user friendly interface to allow communication and visualisation of the information.
  • Development and testing of the ultrasonic guided wave system pulser receiver and transducers. The pulser receiver will be controlled by a specially developed software application that provides high versatility for the waveform generation and several signal analysis tools.

Project Partners


Meet the Principal Investigator(s) for the project

Professor Tat-Hean Gan

Related Research Group(s)

woman engineer

Brunel Innovation Centre - A world-class research and technology centre that sits between the knowledge base and industry.


Partnering with confidence

Organisations interested in our research can partner with us with confidence backed by an external and independent benchmark: The Knowledge Exchange Framework. Read more.


Project last modified 18/03/2021